K71000 Koehler Automatic Pensky-Martens Closed Cup Flash Point Analyzer
Hover to Zoom

Sell K71000 Koehler Automatic Pensky-Martens Closed Cup Flash Point Analyzer



Specification of K71000 Koehler Automatic Pensky-Martens Closed Cup Flash Point Analyzer

Laboratory Tools

Test Method
For flash point determination of distillate fuels, biodiesel, new residual fuel oils, lubricating oils, cutback residua, used lubricating oils, mixtures of petroleum liquids with solids, petroleum liquids that tend to form a surface film during testing. .

Automated Pensky-Martens Flash Point Analyzer
• Conforms to ASTM D93 and relatEd specifications
• Flash Point Detection by Thermocouple and Ionization Ring
• Electric or Gas ignition: Software selectable, the User Friendly Manual Switching
• Operation Flash Point range between Ambient and 405 ° C
• Integrated Dual Fan System directly cools the test cup and surrounding environment
• 8.4 "LCD Touch Screen Interface makes for easy viewing and navigation
• Automatic Barometric Pressure Correction
• Fire Suppression System floods instrument with inert gas in the event of a fire

The Automated Pensky-Martens Flash Point Analyzer represents a perfect union of next-generation technology with traditional robust quality. The system software runs on an integrated PC processor running the latest Windows operating system. The 8.4 "touch screen interface fully displays the all operator parameters and results on a single screen. A three (3) position of mechanical lift system for the cover and the motor is assembly is fully automated and software selectable: Open – Clean – Test for one touch positioning of the test cup. Comes standard with two flash detector systems including a thermocouple and ionization ring detection. Over 65.000 results of data can be stored on the local hard drive. Integrated Dual Fan System directly cools the test cup and the environment around the test cup. Unlimited number of user programs including a quick test that safely tests from ambient, puts the flash point result into tHe official run of the EFP, and prompts the user to refresh the sample, virtually assuring no fires ever occur.4womenonly. In addition, the instrument comes standard with an inert gas fire suppression system.

Specifications
Conforms to the specifications of:
ASTM D93 Procedure A, B and C; IP 34; ISO 2719; DIN EN 22719;
JIS K2265; NF M 07-019
Detection System: Thermocouple and Ionization Ring
Temperature Range: Ambient-405 ° C
Heating Rate: In accordance to ASTM D93 procedure A, B and C
Stirring Rate: 0 to 300 ± 5 RPM,
Cycle Time: 5 minutes as per rapid fan cooling system
Ignition Test Frequency: User selectable on a per method basis
Cooling: Integrated Dual Fan System: First (1) directly to cup, Second
(2) to cool the environment around the test cup
Barometric Pressure The Barometric Pressure Correction: Automatic
Methods of Data Storage: & Limited only by the PC hard disk drive space
Temperature Calibration: Three Types come standard:
-2 Point Sample Temperature
-Multipoint (> 2) Temperature Calibration
-CRM Calibration – built-in Software function to automatically correct
as per CRM tested
Communication:-Ethernet Connectivity via LIMS and RS 232 ports
-Two (2) USB ports (1 – 2 – Frontm Back)
Security: Three (3) levels password protection
Safety: Fire prevention, detection, and suppression systems standardBr/> Electrical Requirements:
110-240V 50/60 Hz

Dimensions wxdxh, in. (cm)
10,875 x 17.5 x 26 (27.63 x 44.45 x 66.04)
Net Weight: 60 lbs. (27.22 kg)

 

Ordering Information

Catalog
Number Product Description        

K71000 Automatic Pensky-Martens Closed Cup Flash Point Analyzer, 110-240V 50/60 Hz